summaryrefslogtreecommitdiffstats
path: root/assets/js
diff options
context:
space:
mode:
Diffstat (limited to 'assets/js')
-rw-r--r--assets/js/vue/vue-lantiq-eeprom.vue191
1 files changed, 145 insertions, 46 deletions
diff --git a/assets/js/vue/vue-lantiq-eeprom.vue b/assets/js/vue/vue-lantiq-eeprom.vue
index 35176d4..098cca6 100644
--- a/assets/js/vue/vue-lantiq-eeprom.vue
+++ b/assets/js/vue/vue-lantiq-eeprom.vue
@@ -8,8 +8,8 @@
<template v-if="type === 'eeprom-lantiq'">
<div class="form-floating mb-3">
<select class="form-control" placeholder="Select EEPROM" id="eeprom-type" v-model="eeprom_switch">
- <option value="0">EEPROM A0</option>
- <option value="1">EEPROM A2</option>
+ <option value="A0">EEPROM A0</option>
+ <option value="A2">EEPROM A2</option>
</select>
<label for="eeprom-type">Select EEPROM A0 or A2</label>
</div>
@@ -43,8 +43,8 @@
<template v-if="type === 'eeprom-ethtool'">
<div class="form-floating mb-3">
<select class="form-control" placeholder="Select EEPROM" id="eeprom-type" v-model="eeprom_switch">
- <option value="0">EEPROM A0</option>
- <option value="1">EEPROM A2</option>
+ <option value="A0">EEPROM A0</option>
+ <option value="A2">EEPROM A2</option>
</select>
<label for="eeprom-type">Select EEPROM A0 or A2</label>
</div>
@@ -122,8 +122,8 @@ export default {
eeprom_decode: null,
lantiq_0: null,
lantiq_last: null,
- eeprom_table: [
- [
+ eeprom_table: {
+ "A0":[
{
"address": "",
"size": "",
@@ -135,21 +135,21 @@ export default {
"size": "1",
"name": "Identifier",
"description": "Type of transceiver",
- "parse": "table_3_2"
+ "parse": "table_identifier_values"
},
{
"address": "1",
"size": "1",
"name": "Ext identifier",
"description": "Additional information about the transceiver",
- "parse": "table_3_3"
+ "parse": "table_phy_device_identifier_value"
},
{
"address": "2",
"size": "1",
"name": "Connector",
"description": "Type of media connector",
- "parse": "table_3_4"
+ "parse": "table_connector_value"
},
{
"address": "3-10",
@@ -162,7 +162,7 @@ export default {
"size": "1",
"name": "Encoding",
"description": "High speed serial encoding algorithm",
- "parse": "table_3_6"
+ "parse": "table_encoding_value"
},
{
"address": "12",
@@ -230,7 +230,8 @@ export default {
"address": "36",
"size": "1",
"name": "Transceiver",
- "description": "Code for optical compatibility"
+ "description": "Code for optical compatibility",
+ "parse":"table_extended_specification_compliance_codeds"
},
{
"address": "37-39",
@@ -313,21 +314,21 @@ export default {
"size": "1",
"name": "Diagnostic Monitoring Type",
"description": "Indicates which type of diagnostic monitoring is implemented",
- "parse":"table_3_9"
+ "parse":"table_diagnostic_monitoring_type"
},
{
"address": "93",
"size": "1",
"name": "Enhanced Options",
"description": "Indicates which optional enhanced features are implemented",
- "parse":"table_3_10"
+ "parse":"table_enhanced_options"
},
{
"address": "94",
"size": "1",
"name": "SFF-8472 Compliance",
"description": "Indicates which revision of SFF-8472 the transceiver complies with",
- "parse":"table_3_12"
+ "parse":"table_compliance"
},
{
"address": "95",
@@ -367,7 +368,7 @@ export default {
"description": "Reserved"
}
],
- [
+ "A2":[
{
"address": "",
"size": "",
@@ -688,7 +689,7 @@ export default {
"size": "1",
"name": "Status/Control",
"description": "Optional Status and Control Bits",
- "parse": "table_3_17"
+ "parse": "table_real_time_diagnostic_and_control"
},
{
"address": "111",
@@ -701,26 +702,29 @@ export default {
"size": "2",
"name": "Alarm Flags",
"description": "Diagnostic Alarm Flag Status Bits",
- "parse": "table_3_18"
+ "parse": "table_alarm_and_warning"
},
{
"address": "114",
"size": "1",
"name": "Tx Input EQ control",
- "description": "Tx Input equalization level control"
+ "description": "Tx Input equalization level control",
+ "parse": "hex_to_dBm"
+
},
{
"address": "115",
"size": "1",
"name": "Rx Out Emphasis control",
- "description": "Rx Output emphasis level control"
+ "description": "Rx Output emphasis level control",
+ "parse": "hex_to_dBm"
},
{
"address": "116-117",
"size": "2",
"name": "Warning Flags",
"description": "Diagnostic Warning Flag Status Bits",
- "parse": "table_3_18"
+ "parse": "table_alarm_and_warning"
},
{
"address": "118-119",
@@ -843,17 +847,17 @@ export default {
"description": "Reserved"
}
]
- ],
- eeprom_switch: 0
+ },
+ eeprom_switch: "A0"
}
},
props: ['type'],
computed: {
revision: {
get() {
- if (this.eeprom_switch === 0) {
+ if (this.eeprom_switch === "A0") {
var rev = this.getPart(94, 94);
- return rev !== "00" ? this.table_3_12(rev).slice(0, -1) ?? "SFF-8472" : "SFF-8472";
+ return rev !== "00" ? this.table_compliance(rev).slice(0, -1) ?? "SFF-8472" : "SFF-8472";
}
return "SFF-8472";
}
@@ -878,10 +882,10 @@ export default {
var lantiq_array = val.split('@');
this.lantiq_0 = lantiq_array.shift();
if(this.lantiq_0.includes("sfp_a2_info")) {
- this.eeprom_switch = 1;
+ this.eeprom_switch = "A2";
}
else if(this.lantiq_0.includes("sfp_a0_low_128")) {
- this.eeprom_switch = 0;
+ this.eeprom_switch = "A0";
}
this.lantiq_last = lantiq_array.slice(-2);
var lantiq_decode = lantiq_array.map(it => this.base64ToHex(it)).join('');
@@ -900,13 +904,15 @@ export default {
};
this.eeprom_decode = [...eeprom_decode];
var ethtool_0 = val.split('\n')[0];
- var conditions0 = ['-m','--dump-module-eeprom','--module-info'];
- var conditions1 = ['-e','--eeprom-dump'];
- if(conditions0.some(el => ethtool_0.includes(el))) {
- this.eeprom_switch = 0;
- }
- else if(conditions1.some(el => ethtool_0.includes(el))) {
- this.eeprom_switch = 1;
+ const conditions = {
+ "A0": ['-m', '--dump-module-eeprom', '--module-info'],
+ "A2": ['-e', '--eeprom-dump']
+ };
+ for (const [key, value] of Object.entries(conditions)) {
+ if (value.some(el => ethtool_0.includes(el))) {
+ this.eeprom_switch = key;
+ break;
+ }
}
}
},
@@ -1146,6 +1152,9 @@ export default {
hexToMac: function(hex) {
return hex ? this.chunk(hex).join(':') : "";
},
+ hex_to_dBm: function(hex) {
+ return hex ? `${parseInt(hex, 16)}dBm` : "";
+ },
hex_suWTo_dBm: function(hex) {
return hex ? `${(10 * Math.log10(parseInt(hex, 16) / 10000)).toFixed(2)}dBm` : "";
},
@@ -1188,13 +1197,15 @@ export default {
}
return list;
},
- table_3_2: function (hex) {
+ table_identifier_values: function (hex) {
var table = {
- "03":"SFP",
+ "01":"GBIC",
+ "02":"Module soldered to motherboard (ex: SFF)",
+ "03":"SFP/SFP+/SFP28"
}
return hex ? table[hex] ?? `See ${this.revision} Table 3.2` : "";
},
- table_3_3: function (hex) {
+ table_phy_device_identifier_value: function (hex) {
var table = {
"00":"GBIC definition is not specified or the GBIC definition is not compliant with a defined MOD_DEF. See product specification for details",
"01":"GBIC is compliant with MOD_DEF 1",
@@ -1207,16 +1218,24 @@ export default {
}
return hex ? table[hex] ?? `See ${this.revision} Table 3.3` : "";
},
- table_3_4: function (hex) {
+ table_connector_value: function (hex) {
var table = {
"00":"Unknown or unspecified",
- "01":"SC",
- "07":"LC",
- "22":"RJ45",
+ "01":"SC (Subscriber Connector)",
+ "02":"Fibre Channel Style 1 copper connector",
+ "03":"Fibre Channel Style 2 copper connector",
+ "04":"BNC/TNC (Bayonet/Threaded Neill-Concelman)",
+ "05":"Fibre Channel coax headers",
+ "06":"Fiber Jack",
+ "07":"LC (Lucent Connector)",
+ "08":"MT-RJ (Mechanical Transfer - Registered Jack)",
+ "09":"MU (Multiple Optical)",
+ "21":"Copper pigtail",
+ "22":"RJ45 (Registered Jack)"
}
return hex ? table[hex] ?? `See ${this.revision} Table 3.4` : "";
},
- table_3_6: function (hex) {
+ table_encoding_value: function (hex) {
var table = {
"00":"Unspecified",
"01":"8B/10B",
@@ -1228,7 +1247,7 @@ export default {
}
return hex ? table[hex] ?? `See ${this.revision} Table 3.6` : "";
},
- table_3_17: function(hex) {
+ table_real_time_diagnostic_and_control: function(hex) {
var table = {
128:"TX Disable State",
64:"Soft TX Disable",
@@ -1241,7 +1260,7 @@ export default {
}
return hex ? this.flagDecoder(hex, table)?.join(', ') : "";
},
- table_3_18: function(hex) {
+ table_alarm_and_warning: function(hex) {
var table = [{
128:"Temp High",
64:"Temp Low",
@@ -1257,7 +1276,7 @@ export default {
}]
return hex ? this.chunk(hex)?.flatMap((element, index) => this.flagDecoder(element, table[index]))?.join(', ') : "";
},
- table_3_9: function(hex) {
+ table_diagnostic_monitoring_type: function(hex) {
var table = {
64:"Digital diagnostic monitoring implemented",
32:"Internally calibrated",
@@ -1272,7 +1291,7 @@ export default {
}
return hex ? this.flagDecoder(hex, table, not_table)?.join(', ') : "";
},
- table_3_10: function(hex) {
+ table_enhanced_options: function(hex) {
var table = {
128:"Alarm/warning flags implemented for all monitored quantities",
64:"Soft TX_DISABLE control and monitoring implemented",
@@ -1284,7 +1303,7 @@ export default {
}
return hex ? this.flagDecoder(hex, table)?.join(', ') : "";
},
- table_3_12: function(hex) {
+ table_compliance: function(hex) {
var table = {
"00":"Digital diagnostic functionality not included or undefined.",
"01":"Rev 9.3 of SFF-8472.",
@@ -1299,6 +1318,86 @@ export default {
}
return hex ? table[hex] ?? "" : "";
},
+ table_extended_specification_compliance_codeds: function(hex) {
+ var table = {
+ "00":"Unspecified.",
+ "01":"100G AOC (Active Optical Cable), retimed or 25GAUI C2M AOC. Providing a worst BER of 5 × 10-5.",
+ "02":"100GBASE-SR4 or 25GBASE-SR.",
+ "03":"100GBASE-LR4 or 25GBASE-LR.",
+ "04":"100GBASE-ER4 or 25GBASE-ER.",
+ "05":"100GBASE-SR10.",
+ "06":"100G CWDM4.",
+ "07":"100G PSM4 Parallel SMF.",
+ "08":"100G ACC (Active Copper Cable), retimed or 25GAUI C2M ACC. Providing a worst BER of 5 × 10-5.",
+ "09":"Obsolete (assigned before 100G CWDM4 MSA required FEC).",
+ "0A":"Reserved.",
+ "0B":"100GBASE-CR4, 25GBASE-CR CA-25G-L or 50GBASE-CR2 with RS (Clause91) FEC.",
+ "0C":"25GBASE-CR CA-25G-S or 50GBASE-CR2 with BASE-R (Clause 74 Fire code) FEC.",
+ "0D":"25GBASE-CR CA-25G-N or 50GBASE-CR2 with no FEC.",
+ "0E":"10 Mb/s Single Pair Ethernet (802.3cg, Clause 146/147, 1000 m copper).",
+ "10":"40GBASE-ER4.",
+ "11":"4 x 10GBASE-SR.",
+ "12":"40G PSM4 Parallel SMF.",
+ "13":"G959.1 profile P1I1-2D1 (10709 MBd, 2km, 1310 nm SM).",
+ "14":"G959.1 profile P1S1-2D2 (10709 MBd, 40km, 1550 nm SM).",
+ "15":"G959.1 profile P1L1-2D2 (10709 MBd, 80km, 1550 nm SM).",
+ "16":"10GBASE-T with SFI electrical interface.",
+ "17":"100G CLR4.",
+ "18":"100G AOC, retimed or 25GAUI C2M AOC. Providing a worst BER of 10-12 or below.",
+ "19":"100G ACC, retimed or 25GAUI C2M ACC. Providing a worst BER of 10-12 or below.",
+ "1A":"100GE-DWDM2 (DWDM transceiver using 2 wavelengths on a 1550 nm DWDM grid with a reach up to 80 km).",
+ "1B":"100G 1550nm WDM (4 wavelengths).",
+ "1C":"10GBASE-T Short Reach (30 meters).",
+ "1D":"5GBASE-T.",
+ "1E":"2.5GBASE-T.",
+ "1F":"40G SWDM4.",
+ "20":"100G SWDM4.",
+ "21":"100G PAM4 BiDi.",
+ "37":"10GBASE-BR (Clause 158).",
+ "38":"25GBASE-BR (Clause 159).",
+ "39":"50GBASE-BR (Clause 160).",
+ "22":"4WDM-10 MSA (10km version of 100G CWDM4 with same RS(528,514) FEC in host system).",
+ "23":"4WDM-20 MSA (20km version of 100GBASE-LR4 with RS(528,514) FEC in host system).",
+ "24":"4WDM-40 MSA (40km reach with APD receiver and RS(528,514) FEC in host system).",
+ "25":"100GBASE-DR (Clause 140), CAUI-4 (no FEC).",
+ "26":"100G-FR or 100GBASE-FR1 (Clause 140), CAUI-4 (no FEC on host interface).",
+ "27":"100G-LR or 100GBASE-LR1 (Clause 140), CAUI-4 (no FEC on host interface).",
+ "28":"100GBASE-SR1 (802.3, Clause 167), CAUI-4 (no FEC on host interface).",
+ "3A":"100GBASE-VR1 (802.3, Clause 167), CAUI-4 (no FEC on host interface).",
+ "29":"100GBASE-SR1, 200GBASE-SR2 or 400GBASE-SR4 (802.3, Clause 167).",
+ "36":"100GBASE-VR1, 200GBASE-VR2 or 400GBASE-VR4 (802.3, Clause 167).",
+ "2A":"100GBASE-FR1 (802.3, Clause 140) or 400GBASE-DR4-2 (P802.3df, Clause 124).",
+ "2B":"100GBASE-LR1 (802.3, Clause 140).",
+ "2C":"100G-LR1-20 MSA, CAUI-4 (no FEC on host interface).",
+ "2D":"100G-ER1-30 MSA, CAUI-4 (no FEC on host interface).",
+ "2E":"100G-ER1-40 MSA, CAUI-4 (no FEC on host interface).",
+ "2F":"100G-LR1-20 MSA.",
+ "34":"100G-ER1-30 MSA.",
+ "35":"100G-ER1-40 MSA.",
+ "30":"Active Copper Cable with 50GAUI, 100GAUI-2 or 200GAUI-4 C2M. Providing a worst BER of 10-6 or below.",
+ "31":"Active Optical Cable with 50GAUI, 100GAUI-2 or 200GAUI-4 C2M. Providing a worst BER of 10-6 or below.",
+ "32":"Active Copper Cable with 50GAUI, 100GAUI-2 or 200GAUI-4 C2M. Providing a worst BER of 2.6x10-4 for ACC, 10-5 for AUI, or below.",
+ "33":"Active Optical Cable with 50GAUI, 100GAUI-2 or 200GAUI-4 C2M. Providing a worst BER of 2.6x10-4 for AOC, 10-5 for AUI, or below.",
+ "3F":"100GBASE-CR1, 200GBASE-CR2 or 400GBASE-CR4 (P802.3ck, Clause 162).",
+ "40":"50GBASE-CR, 100GBASE-CR2, or 200GBASE-CR4.",
+ "41":"50GBASE-SR, 100GBASE-SR2, or 200GBASE-SR4.",
+ "42":"50GBASE-FR or 200GBASE-DR4.",
+ "4A":"50GBASE-ER (IEEE 802.3, Clause 139).",
+ "43":"200GBASE-FR4.",
+ "44":"200G 1550 nm PSM4.",
+ "45":"50GBASE-LR.",
+ "46":"200GBASE-LR4.",
+ "47":"400GBASE-DR4 (802.3, Clause 124), 400GAUI-4 C2M (Annex 120G).",
+ "48":"400GBASE-FR4 (802.3, Clause 151).",
+ "49":"400GBASE-LR4-6 (802.3, Clause 151).",
+ "4B":"400G-LR4-10.",
+ "4C":"400GBASE-ZR (P802.3cw, Clause 156).",
+ "7F":"256GFC-SW4 (FC-PI-7P).",
+ "80":"64GFC (FC-PI-7).",
+ "81":"128GFC (FC-PI-8)."
+ }
+ return hex ? table[hex] ?? "" : "";
+ },
asciiToHex: function(str) {
return ([...str].map((_, n) => Number(str.charCodeAt(n)).toString(16)).join(''));
},