diff options
author | martinbra <martinbra@gmail.com> | 2020-07-30 05:21:11 +0200 |
---|---|---|
committer | martinbra <martinbra@gmail.com> | 2020-07-30 05:21:11 +0200 |
commit | 2e73f1aec042986fae435d68cacafcba8b8ec49f (patch) | |
tree | a90e5eff739ab474b9a8d4df71a28ac55352107d /examples/Alert_Window_Mode_with_Latch | |
parent | Adding keywords.txt for the Arduino lazy sintax highlighting. (diff) | |
download | ADS1115_WE-2e73f1aec042986fae435d68cacafcba8b8ec49f.tar ADS1115_WE-2e73f1aec042986fae435d68cacafcba8b8ec49f.tar.gz ADS1115_WE-2e73f1aec042986fae435d68cacafcba8b8ec49f.tar.bz2 ADS1115_WE-2e73f1aec042986fae435d68cacafcba8b8ec49f.tar.lz ADS1115_WE-2e73f1aec042986fae435d68cacafcba8b8ec49f.tar.xz ADS1115_WE-2e73f1aec042986fae435d68cacafcba8b8ec49f.tar.zst ADS1115_WE-2e73f1aec042986fae435d68cacafcba8b8ec49f.zip |
Diffstat (limited to 'examples/Alert_Window_Mode_with_Latch')
-rw-r--r-- | examples/Alert_Window_Mode_with_Latch/Alert_Window_Mode_with_Latch.ino | 8 |
1 files changed, 4 insertions, 4 deletions
diff --git a/examples/Alert_Window_Mode_with_Latch/Alert_Window_Mode_with_Latch.ino b/examples/Alert_Window_Mode_with_Latch/Alert_Window_Mode_with_Latch.ino index 049a65f..f90d6db 100644 --- a/examples/Alert_Window_Mode_with_Latch/Alert_Window_Mode_with_Latch.ino +++ b/examples/Alert_Window_Mode_with_Latch/Alert_Window_Mode_with_Latch.ino @@ -83,14 +83,14 @@ void setup() { */
//adc.setConvRate(ADS1115_8_SPS); //uncomment if you want to change the default
- /* Set continous or single shot mode:
+ /* Set continuous or single shot mode:
*
- * ADS1115_CONTINOUS -> continous mode
+ * ADS1115_CONTINUOUS -> continuous mode
* ADS1115_SINGLE -> single shot mode (default)
*/
- adc.setMeasureMode(ADS1115_CONTINOUS); //comment or change if you want to change single shot
+ adc.setMeasureMode(ADS1115_CONTINUOUS); //comment or change if you want to change single shot
- /* Choose maximum limit or maxium and minimum alert limit (window)in Volt - alert pin will
+ /* Choose maximum limit or maximum and minimum alert limit (window)in Volt - alert pin will
* be active when measured values are beyond the maximum limit or outside the window
* Upper limit first: setAlertLimit_V(MODE, maximum, minimum)
* In max limit mode the minimum value is the limit where the alert pin will be deactivated
|